Powered by Dragonfly Energy Graphic
FREE GROUND SHIPPING*

Blog

What’s The Difference Between Wiring Batteries in Series Vs. Parallel?

Table of Contents

Understanding the difference between wiring batteries in series vs. parallel is critical if you have multiple batteries. How you connect your batteries will determine how they perform in different applications. Let’s look at how to wire batteries in series vs. parallel and when each method is appropriate. 

Battle Born Batteries

What’s The Difference Between Wiring Batteries in Series Vs. Parallel?

The main difference between wiring batteries in series and parallel is the impact on the output voltage and capacity of the battery system. Batteries wired in series will add their voltages while the capacity stays the same. Conversely, batteries wired in parallel will have their capacities (measured in amp-hours) added together while their voltage remains the same. However, the total available energy (measured in watt-hours) in both configurations is the same.

For example, wiring two 12-volt batteries with 100 Ah capacities in series will output a 24-volt system with a 100 Ah capacity. Wiring the same two batteries in parallel will output a 12-volt system with a 200 Ah capacity. Thus, both systems have a total available energy of 2400 watt-hours (watt-hours = volts x amp-hours).

Additionally, whether batteries are wired in series or parallel configurations, they should always have the same voltage and capacity ratings. Mixing and matching voltages and capacities can lead to problems that may damage your batteries.

Wiring Batteries in Series

To wire multiple batteries in series, connect each battery’s positive terminal to the next’s negative terminal. Then, measure the system’s total output voltage between the negative terminal of the first battery and the positive terminal of the last battery in the series.

For example, two 12-volt 100 Ah batteries are wired in series. As you can see, the positive terminal on the first battery is connected to the negative terminal on the second. Thus, the system’s voltage will increase to 24 volts while the total capacity will remain at 100 Ah. 

2 Battle Born Batteries in series graphic

Similarly, with 3 – 12-volt 100Ah batteries wired in series, the voltages of all three batteries add together, resulting in a system voltage of 36 volts and a capacity of 100 Ah.

3 Battle Born Batteries in series graphic

Advantages

The power a device consumes equals its operating voltage multiplied by the current it draws. For example, a 360-watt device operating at 12 volts would draw 30 amps (12 x 30 = 360), while the same device operating at 24 volts would only draw 15 amps (24 x 15 = 360).

Wiring batteries in series provides a higher system voltage, resulting in a lower system current. Less current means you can use thinner wiring and suffer less voltage drop in the system. 

Charging and power drawing work the same way. Consider an MPPT solar charge controller rated at 50amps. A 50A x 12V controller can only handle 600 watts of solar, but at 24Vx50A, it can handle 1200 watts!

In general, larger power systems can benefit from running batteries in series at higher voltages.

Battle Born Batteries power system

Disadvantages

In a battery system wired in series, you cannot obtain lower voltages from the battery bank without using a converter. All equipment needs to function at the higher voltage, or an additional converter is required to use 12V appliances.

How Many Batteries Can You Wire In Series?

The limit on how many batteries you can wire in series typically depends on the battery and manufacturer. At Battle Born Batteries, we recommend that up to four batteries be wired together in series, creating a 48-volt system. Always check with your battery manufacturer to ensure you do not exceed their recommended limit.

Wiring Batteries in Parallel

To wire multiple batteries in parallel, connect all of the positive terminals together and then all of the negative terminals together. Since all positive and negative terminals are connected, you can measure the system output voltage across any of the positive and negative battery terminals.

Battle Born Batteries wired in parallel

For example, two 12-volt 100 Ah batteries are wired in parallel. The positive terminal on the first battery connects to the positive terminal on the second. Likewise, the negative terminals of both batteries are also connected. The system has a voltage of 12 volts and a total capacity of 200 Ah. 

2 Battle Born Batteries in parallel

The same principles apply when adding a third battery. The capacities of all three batteries add up to a total capacity of 300 Ah at 12 volts.

three 3 Battle Born Batteries in parallel

Advantages

The main advantage of wiring batteries in parallel is that you increase your system’s available runtime while maintaining the voltage. Since the amp-hour capacities are additive, two batteries in parallel double your runtime, three batteries triple it, and so on.

Another advantage to wiring batteries in parallel is that if one of your batteries dies or has an issue, the remaining batteries in the system can still provide power. 

Disadvantages

The main drawback to wiring batteries in parallel vs. series is that the system voltage will be lower, resulting in a higher current draw. Higher current means thicker cables and more voltage drop. Larger power appliances and generation are less efficient when operating at lower voltages.

Battle Born Batteries power system
Thai Burger Food Truck Stills

How Many Batteries Can You Wire In Parallel?

There is no limit to how many batteries you can wire in parallel. The more batteries you add in a parallel circuit, the more capacity and longer runtime you will have available. Remember that the more batteries you have in parallel, the longer it will take to charge the system.

Huge parallel battery banks also have much higher current availability. This means the proper system fusing is critical to prevent accidental shorts that could have catastrophic consequences with so much current available.

Can You Wire Batteries in Series and Parallel?

You cannot simultaneously wire individual batteries in series and parallel without shorting the system. However, you can wire batteries in series and connect the sets in parallel to form a larger battery bank with a higher voltage.

The photo below shows a portion of a battery bank. Four 12-volt 270 Ah GC3 Battle Born Batteries are wired together in series to increase the voltage. This creates a 48-volt 270Ah system. Think of each set of four batteries wired together as one battery. To wire them in parallel, you must “create” another set of batteries equal to the voltage of the first. The system below includes 16 sets of 48V “batteries” wired together for 48 volts and 4,320Ah.

Battle Born Batteries wired in series and parallel
series parallel Battle Born batteries

Charging Batteries in Series Vs. Parallel

Besides ensuring you have the correct voltage charger, batteries in series vs. parallel charge the same way.

Series

For batteries wired in series, connect the positive charger cable to the positive terminal on the first battery in the series and the negative charger cable to the negative terminal on the last battery in the series.

Parallel

For even charging across a parallel bank, connect your charge similarly: positive connection to the first battery and negative connection to the last battery.

Optionally, a multi-bank battery charger may provide faster charge times for series and parallel battery banks. Refer to the manufacturer’s recommendation for the best way to charge your batteries. 

โžก Read our article on Charging Lithium Batteries: The Basics.

Battle Born Batteries

FAQ: Do Batteries Last Longer In Series Or Parallel?

Series connections provide a higher voltage, which is slightly more efficient. This means that batteries wired in series can last marginally longer than batteries wired in parallel. However, overall performance remains the same, and batteries connected in series and parallel will provide roughly the same runtime. Let’s look at a quick example explaining why this is true.

Two 12-volt batteries with a 100 Ah capacity power a 240-watt device. These two batteries, wired in series, will provide 24 volts and 100 Ah capacity. The device’s current draw will be ten amps (24 x 10 = 240). Thus, the theoretical runtime is ten hours: 100 Ah divided by 10 amps. 

Conversely, the same two parallel batteries provide 12 volts and 200 Ah of capacity. The device’s current draw in this setup is 20 amps (12 x 20 = 240). Thus, the theoretical runtime is also ten hours: 200 Ah divided by 20 amps. 

Batteries in Series Vs. Parallel: Which Is For You?

Choosing whether to connect your batteries in series or parallel depends on the specific needs of the devices you are powering. For general boat and RV applications, wiring batteries in parallel provides the most uncomplicated wiring and standard voltage. However, higher-voltage series connections might be best for large applications beyond 3000 watts. Now that you understand how each wiring configuration works, you can determine the best option for your needs and proceed confidently. 

Want To Learn More About Electrical Systems and Lithium Batteries?

We know that building or upgrading an electrical system can be overwhelming, so we’re here to help. Our Reno, Nevada-based sales and customer service team is standing by at (855) 292-2831 to take your questions!

Also, join us on Facebook, Instagram, and YouTube to learn more about how lithium battery systems can power your lifestyle, see how others have built their systems, and gain the confidence to get out there and stay out there.


Share this

29 thoughts on “What’s The Difference Between Wiring Batteries in Series Vs. Parallel?

    1. Hi Mark. In a battery system wired in series, you cannot get lower voltages off the battery bank without using a converter. Either all equipment needs to function at the higher voltage or an additional converter is needed to use 12V appliances on the system. Unless you have an additional converter, it would be best to wire your batteries in parallel.

  1. if you wire 2 12volt batteries in series, one 100amp the other 200 amp what amperage will the result have?
    same question if wired in parallel?

  2. So we get the same run time from 12 volt vs 24 volt but what about the charging time? Won’t the 24 volt system with the two batteries at 100 AH charge quicker than the 12 volt system with 200 AH capacity? The system I will be using charges at 25 Amps.

    1. Yes, a 100Ah system being charged at 25 amps will charge quicker than a 200Ah system being charged at 25 amps.

  3. Excellent explanation – thanks!
    Can I assume if I was using a trickle charger for a single battery, I can continue to use that for a parallel setup?

    1. Hi Adam! There are not differing effects on the life of the our batteries depending on how you wire it. Whether you wire in parallel or series, the life span of the battery will remain the same.

  4. Hi, a great explanation of batteries in series/parallel…thanks!

    A couple of assumptions and questions, based on your Figure 15 diagram above:
    – Assume batteries are, from left to right, 1, 2, 3 and 4
    – All batteries are 100ah
    – Batteries 1 and 2 together, and 3 and 4 together are serially connected
    – Batteries 1 and 2 together, and 3 and 4 together constitute 2x 24v “batteries”

    Question 1: If charging positive is connected to positive on battery 1, and charging negative is connected to negative on battery 4, that would create (essentially) 2x 24v 200ah banks connected in parallel. Is that correct?

    Question 2: I currently have a 2400VA inverter installed, with 2x 12v 100ah batteries in series for a 24v bank, but want to extend the runtime by adding more batteries. If I am correct, the above should cater for that extension?

    Look forward to hearing from you soon…

    1. Hi Steven!
      Question 1: Yes, that would create a 24V 200Ah bank.
      Question 2: Yes, doing that would extend your runtime.

  5. Hello!
    In terms of wire length for series and parallel connection should it all be the same length or two diferent lengths as in the picture above?

    Thank you!!!

    1. Hi John! Due to the angle of the diagram it may appear that the wires are different lengths but they are not. Always be sure that all of your connection cables, whether in series or in parallel, or the same length.

        1. That is the heat enable cable, which would only be relevant if you were using our heated batteries.

    1. Take the total amp hours of the bank and divide by the hourly charging rate of your charger to get the total amount of time it will take to charge your bank.

  6. If you have four 12v-100a batteries connected in series for 48v can you add a fifth battery in parallel to get 200a?

    1. Hi Larry. You cannot do that. For a 48V 200Ah system you would need 8 batteries with 2 sets of 48V series wired together in parallel.

  7. Hi, our setup is catamaran that has two large Yanmar V8 and on each I think 120A alternators, that are wired each through its own Blue Sea ACR to house battery bank, when we replace the AGM batteries with your LifePO4 it seems to me we would (1) have a lot more Ah capacity in the house bank that (2) would try and draw a lot more Amps when they see a source. Source could be shore power or generator through a Victron hybrid inverter charger and we will go solar that I think connects via MPPT regulator to the Victron. So key question : would we need a current limiting device installed between the ACR and your batteries??? My concern is overheating the Yanmar alternators when vessel is at idle and batteries are hungry. Thank you in advance

  8. Hi, great write up. I have a question.

    I want to build up a small system for home only. I want to power a fridge some LED lights and perhaps the TV for blackouts. I just want the longest runtime. Will have solar to charge during the day.

    So, I was thinking 48v system and inverter. Or would 12v be enough (4x 200Ah batteries is what I am thinking)
    Looking at Victron for the inverter/charger/MPPT

    Cheers

    Steve

    1. Hi Steve! We recommend starting with the battery calculator on our website to get a better idea of exactly how many of our batteries and which size you would need based on your specific application. You can find the battery calculator here: https://battlebornbatteries.com/learn/calculator/ Then our technical sales team would love to help you configure the rest of your system. You can reach them at (855) 292-2831 (M-F 8:00am-4:30pm (PST)) or [email protected].

  9. We have 6/12volt 100ah lithium battle born batteries
    If we connect them in series and parallel how many ah do we end up with
    We have a 2000watt 24 volt inverter

    1. For a 24V system with 6 – 12V 100Ah Battle Born Batteries in series-parallel connection, you would have 24V and 300Ah for your total system.

  10. Great breakdown of wiring configurations! I appreciate the clear explanations of the pros and cons of series versus parallel setups. It’s helped me decide how to configure my battery bank for optimal performance. Thanks for the insights!

Leave a Reply

Your email address will not be published. Required fields are marked *

Shop Best Sellers

100Ah 12V LiFePO4 Deep Cycle Battery

100Ah 12V GC2 LiFePO4 Deep Cycle Battery

270Ah 12V LiFePO4 Deep Cycle GC3 Battery

MultiPlus-II 12/3000/120-50 2x120V (UL)

Victron Lynx Distributor

Rich Solar 200W 12V Panel

Have Questions?

Ask a technical specialist now at 855.292.2831

Stay in the Know