LiFePO4 Battery Isolation Manager (BIM)

$172.10

-

BIM225Li

The LiFePO4 Battery Isolation Manager (BIM) monitors voltage and connects batteries when needed. Under normal charging conditions, the BIM will connect for 15 minutes every 35 minutes. That means that the BIM will connect for 15 minutes, disconnect for 20 minutes, and repeat this cycle until the coach battery is charged.

Need Help?

Ask a technical specialist now at 855.292.2831

You Might Also Like

You may also like…

Product Description

If the coach battery resting voltage exceeds 13.4 V then the BIM will disconnect. A resting voltage greater than 13.4 V indicates a fully charged battery. Note that โ€œresting voltageโ€ means that no current is flowing to the coach battery.

The BIM will disconnect if the alternator voltage exceeds 14.4 V. This protects the coach battery from overcharging. The LiFePO4 Battery Isolation Manager will disconnect if the voltage difference between the alternator and the coach battery is less than 0.1 V. If the voltage difference is too low, then there is a negligible charging current, and no need to connect to the coach battery.

The BIM will disconnect if the alternator voltage drops below 13.3 V. If the alternator voltage is too low, then it cannot adequately charge the coach battery, so there is no reason to connect.

Features

Features

Dimensions: (3″W x 5-1/4″ H x 2″D)

Documentation

Download product documentation for the LiFePO4 Battery Isolation Manager (BIM), including Product Manuals, Cutsheets, Data Sheets, Quick Install Guides, Firmware Updates, Configurations, and more.